Bell Annealing Furnace for Aluminium Foil

Bell Annealing Furnace for Aluminium Foil

Gas-fired bell furnace for annealing capacitor-grade aluminium foil coils under argon (or nitrogen). The inner cover is hydraulically clamped, the load space is evacuated and back-filled after charging, and the whole cycle runs automatically to give uniform, repeatable results without foil sticking.

Gas-fired · argon atmosphere · vacuum purge
Foil coil stack being charged

Our aluminium-foil bell furnace offers industry-leading technical performance; the related equipment images have been blurred.

Main technical data

Heating
Natural-gas firing
Atmosphere
Argon / nitrogen
Reference charge
28 coils, 480 kg each, stack 13.44 t
Coil size (reference)
OD 680 mm, ID 76 mm, width 500 mm, thickness 0.1 mm
Hot / cold spot
540 / 535 °C
Annealing / cooling time
26.0 h / 15.0 h
Base cycle
43.5 h (about 309 kg/h)
Energy (reference)
gas approx. 210 kWh/t, electricity approx. 310 kWh/t
Gas consumption (reference)
nitrogen approx. 10–20 m³/t, argon approx. 30–50 m³/t

Reference-case performance, assuming no foil sticking; actual values depend on material and process.

Process and engineering notes

Capacitor foil has strict requirements for surface cleanliness, oxide condition and recrystallized structure. Annealing normally takes place above 500 °C in an inert atmosphere, and coils must be thoroughly degreased so that rolling oil does not carbonize.

Vacuum purging and inert protection throughout the cycle limit surface oxidation and oil residue, while tightly controlled heating, soaking and cooling prevent the foil layers from sticking together.

Applications

Annealing of capacitor foil, electronic foil and other aluminium foil coils with high surface-quality requirements.

Engineering focus

  • Hydraulically clamped inner cover; load space evacuated then filled with argon or nitrogen, reaching 2×10⁻³ Torr within 30 min (empty, dry, room temperature)
  • High-velocity burners with pulse and proportional control; online monitoring of combustion-chamber pressure, temperature and flue-gas oxygen
  • Temperature accuracy ±1 °C; heating and cooling rate control to 0.5 °C/min
  • Forced base circulation and a central recuperator for uniformity and lower energy use
  • S7-1500 PLC with central HMI; 10-segment temperature and 10-segment atmosphere programmes, full batch traceability and remote diagnostics

Scope of supply

Bases, inner covers with hydraulic clamping, gas-fired heating hoods, cooling hoods, vacuum unit, valve stands, utility piping and automation, with installation, commissioning and operator training.

RFQ DATA

Alloy and temper, foil thickness, coil width/diameter/weight, target properties and surface requirements, annual output, utility conditions.

Need detailed technical data?

For performance data, configuration proposals or reference-site visits, please contact the Hengyuan sales team.